TLC Plates
- (2)
- (2)
- (1)
- (2)
- (19)
- (1)
- (5)
- (1)
- (3)
- (1)
- (1)
- (11)
- (4)
- (3)
- (3)
- (1)
- (3)
- (1)
- (1)
- (103)
- (1)
- (4)
- (28)
- (3)
- (1)
- (3)
- (1)
- (1)
- (155)
- (1)
- (1)
- (1)
- (5)
- (1)
- (2)
- (5)
- (11)
- (32)
- (2)
- (2)
- (2)
- (6)
- (2)
- (1)
- (1)
- (6)
- (1)
- (2)
- (1)
- (1)
- (2)
- (1)
- (3)
- (1)
- (2)
- (3)
- (5)
- (1)
- (11)
- (1)
- (1)
- (1)
- (2)
- (16)
- (2)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (1)
- (5)
- (1)
- (16)
- (1)
- (2)
- (2)
- (37)
- (1)
- (1)
- (2)
- (8)
- (2)
- (7)
- (1)
- (1)
- (6)
- (1)
- (3)
- (1)
- (1)
- (1)
- (3)
- (1)
- (2)
- (60)
- (1)
- (1)
- (2)
- (1)
- (2)
- (6)
- (1)
- (11)
Filtered Search Results

MilliporeSigma™ Supelco™ Silica Gel on TLC Al foils, Binder Polymeric, 200 μm
Silica gel on TLC Alu foils may be used to perform thin layer chromatography.
Color | White |
---|
MilliporeSigma™ TLC Silica Gel 60 F254: 200 Glass plates, 5 x 10cm
Allows analyzation of any substance when combined with suitable mobile phase
MilliporeSigma™ Precoated Aluminum-Backed TLC Sheets

For analytical TLC or high-performance analytical TLC
Thickness (Metric) | 200 μm |
---|---|
Specific Surface | 520 m2/g |
Pore Size | 60 Å |
Particle Size | 10 to 12 μm |
Height (Metric) | 30 μm |
Type | Classical Silica TLC Plate |
Analysis Time | 20 to 200 min. |
Particle Size Distribution | 5 to 20 μm |
No. of Samples | 10.0 |
Excitation Wavelength | 254 nm |
Backing Material | Aluminum |
Height (English) | 0.0011 in. |
Pore Volume | 0.8 mL/g |
MilliporeSigma™ TLC Silica Gel 60 F254: 100 Glass plates, 5 x 20cm
Allows analyzation of any substance when combined with suitable mobile phase
MilliporeSigma™ Precoated HPTLC Glass Plates
Smaller size and distribution of HPTLC media yields improved resolution, shorter analysis times, and higher detection sensitivity
Thickness (Metric) | 200 μm |
---|---|
Type | Silica HPTLC Plate |
Dimensions (L x W) | 20 x 20 cm |
---|
MilliporeSigma™ TLC LuxPlate™ Silica Gel 60 F254: 25 Glass plates, 20 x 20cm
Allows analyzation of any substance when combined with suitable mobile phase
Thickness (Metric) | 200 μm |
---|---|
Pore Size | 60 Å |
Length (Metric) | 20 cm |
Quantity | 25/Pk. |
Backing Material | Aluminum |
Width (Metric) | 20 cm |
Dimensions (L x W) | 20 x 20 cm |
MilliporeSigma™ Supelco™ Nano-Silica Gel RP-18W on Alu-foil for HPTLC with Fluorescent Indicator, Aluminum Cards, 150 μm
RP-18W plates are used in 2D TLC (two-dimensional thin layer chromatography) systems to develop reversed-phase chromatograms.
MilliporeSigma™ Supelco™ TLC Aluminum Sheets, Silica Gel 60 Matrix, Binder Polymeric, 140-160 μm
Silica Gel 60 Matrix TLC plates may be used to perform thin layer chromatography.
MilliporeSigma™ Supelco™ TLC Glass Plates, Silica Gel 60 Matrix with Fluorescent Indicator, Binder Polymeric, 250 μm
Silica Gel 60 Matrix TLC plates may be used to perform thin layer chromatography.
Thickness (Metric) | 250 μm |
---|---|
Pore Size | 60 Å |
Particle Size | 10 to 12 μm |
Material | Glass |
Sorbent | Silica Gel 60 Matrix |
For Use With (Application) | TLC |
Fluorescent Indicator | Yes |
MilliporeSigma™ Supelco™ TLC Aluminum Sheets, Aluminum Oxide Matrix with Fluorescent Indicator, 200 μm
Aluminum Oxide TLC plates may be used to perform thin layer chromatography.
MilliporeSigma™ TLC Silica Gel 60, F254, MS-Grade Glass Plates, 20x20
MS-Grade Glass TLC plates (20 x 20cm) with Silica gel 60 coated with fluorescent indicator F254, 25/Box
MilliporeSigma™ HPTLC RP-modified Silica Gel 60 Plates, Glass Backed

Glass HPTLC Silica gel 60 RP plates
Thickness (Metric) | 200 μm |
---|---|
Pore Size | 60 Å |
Material | Glass |
For Use With (Application) | Separation of Extremely Non-Polar and Highly Polar Substances Using Aqueous Solvent Systems, Fast Analysis of Complex Samples for Manual or Instrumental Use |
Backing Material | Glass |
Width (Metric) | 10 cm |